DIN EN 71-3 RESIN4DECOR Epoxy Resin
Report of Analysis of RESIN4DECOR Epoxy Resin for compliance with the demands of the EN 71-3
Sample Material
For analysis the following sample material was at hand: cured epoxy resin plate
The sample was ground before testing.
Carrying out of the Tests
Examination period: 20 January 2020 to 12 February 2020
Determination of the Migration of Certain Elements
The determination was performed according to DIN EN 71-3:2019-08.
Standard Elements*
The determination was performed by means of ICP-OES in a hydrochloric acid extract.
Result in mg/kg: Limit value
(category Ill)
Aluminium |
(Al): |
not quantifiable |
< |
1,000 |
70,000 |
|
Antimony |
(Sb): |
not quantifiable |
< |
20 |
560 |
|
Arsenic |
(As): |
not quantifiable |
< |
5 |
47 |
|
Barium |
(Ba): |
not quantifiable |
< |
100 |
18,750 |
|
Boron |
(B): |
not quantifiable |
< |
100 |
15,000 |
|
Cadmium |
(Cd): |
not quantifiable |
< |
5 |
17 |
|
Cobalt |
(Co): |
not quantifiable |
< |
20 |
130 |
|
Chromium |
(Cr): |
not quantifiable |
< |
20 |
460 |
- Cr(lll) |
Copper |
(Cu) |
not quantifiable |
< |
20 |
7,700 |
|
Mercury |
(Hg) : |
not quantifiable |
< |
5 |
94 |
|
Manganese |
(Mn): |
not quantifiable |
< |
100 |
15,000 |
|
Nickel |
(Ni): |
not quantifiable |
< |
100 |
930 |
|
Lead |
(Pb): |
not quantifiable |
< |
5 |
23 |
|
Selenium |
(Se): |
not quantifiable |
< |
20 |
460 |
|
Tin |
(Sn): |
not quantifiable |
< |
100 |
180,000 |
|
Strontium |
(Sr) |
not quantifiable |
< |
1,000 |
56,000 |
|
Zinc |
(Zn): |
not quantifiable |
< |
100 |
46,000 |
|
Comment: The overall chromium content including Cr(VI) is recorded under the disintegration conditions.
Chromium(VI)*
The determination was performed according to SOP 162.200 by means of ion chromatography in a buffer solution.
Result:: not quantifiable < 0.05 mg/kg Limit value (Category Ill): 0.053 mg/kg
Organo Tin
The determination was performed in cooperation with the Ostthuringische Materialprufgesell schaft fUr Textil und Kunststoffe mbH (Registration no. D-PL- 11118-01-00) by means of GCMS. The following organo tin compounds were considered:
Monobutyltin, Dibutyltin, Tributyltin, Tetrabutyltin, Monooctyltin, Dioctyltin, Diphenyltin, Triphenyltin, Tricyclohexyltin, Methyltin, Di-n-propyltin
Limit of quantitat ion: 0.9 mg/kg each; sum organo tin compounds : 12 mg/kg
Limit value (Category Ill): 12 mg/kg in total Result:
None of the above-listed compounds were quantifiable .
Comment: The tested sample complies with the limits laid down in the DIN EN 71-3:2019-08.
The accreditation applies to the methods marked with * in the test report (Register no. D-PL-14160-01-01 and D-PL-14160-01-02).